Server spotlight: Four key features of Lenovo’s ThinkSystem SD650

24 Feb 2018

Lenovo’s Data Center Study Tour kicked off at the company’s headquarters in Stuttgart, Germany this week, bringing together partners, customers, analysts and thought leaders.  

During the tour, Lenovo unveiled the third generation of its ThinkSystem SD650 server. A major feature of the server is Lenovo’s direct water cooling design, which challenges traditional air cooling methods by offering better energy efficiency and performance as well as costs savings.

How it works:

Direct water cooling is achieved by circulating the water through cold plates that contact the CPU thermal case, DIMMs, and other high-heat-producing components in the server.

The water flows from the CDU through hoses to the back of the rack. From there, the water is fed into the individual chassis and then distributed via six drop manifolds.

Once the water has done its job, it leaves the servers and returns to the CDU.

The alternative here is an air-cooled system that would need chassis fans in the system to eject heat to the room. The only fans Lenovo’s SD650 servers have are the power supply fans and each enclosure has 6 hot-swap fans that provide any additional heat extraction when needed.

Lenovo’s SD650 server is designed for high-performance computing (HPC), large-scale cloud, and heavy simulation, and supports workloads from technical computing to grid deployments to analytics.

Here are the four key features of Lenovo’s SD650 server:

1. Energy efficiency

A key feature of Lenovo’s SD650’s direct water cooling is that it’s very energy efficient.

According to Lenovo, the SD650 provides up to 40% savings in data center energy, which includes a 25% reduction in annual air conditioning use, a 5% energy savings by running CPUs cooler and a 4% savings by eliminating fans in the compute nodes.

A key differentiator of direct water cooling which Lenovo promotes with its SD650 is that operators can save as much as 40% in the data center due to the reduced need for air conditioning.

Additionally, 85-90% of heat is removed from the servers by water cooling and can be repurposed throughout the data center.

2. Density & design

A dense, flexible solution with low TCO, the design of the ThinkSystem SD650 is beneficial for data centers that need high performance but are limited by floor space.  

By taking up less physical space in the data center, the SD650 enhances density and supports the Intel Xeon Scalable Family of processors up to 28 cores and 205 W TDP.

One n1200 DWC Enclosure houses up to 24 processors with 9.2TB of memory, and accommodates up to 12 SD650 compute nodes each with two Intel Xeon Scalable Family processors, 12 TruDDR4 DIMMs, and one PCIe slot, up to two drive bays, all within 6U of rack space.

And each SD650 offers up to 12 more cores per U than the previous generation.

Density and cost-optimization was a core focus for Lenovo when designing the SD650 which only contains only essential components in the base architecture.

3. Performance

As water cooling removes more heat, the CPUs can run in turbo mode, providing up to 10% great performance, the vendor explained.  

To ramp up performance even more, Lenovo’s SD650 uses 2667MHz DDR4 memory and supports NVMe storage, high-speed EDR InfiniBand, and OmniPath adapters.

4. Quiet

Standing right next to the rack when all servers are in operation and running at maximum performance, the server noise is very minimal, a key advantage of water-cooled system.

For example, if it were an air-cooled rack, you could not have a conversation next to it without having to shout.

Cloud application attacks in Q1 up by 65% - Proofpoint
Proofpoint found that the education sector was the most targeted of both brute-force and sophisticated phishing attempts.
Huawei picks up accolades for software-defined camera ecosystem
"The company's software defined capabilities enable it to future-proof its camera ecosystem and greatly lower the total cost of ownership (TCO), as its single camera system is applicable to a variety of application use cases."
Gartner: Good talent put off by old tech
Technology now ranks in the top ten reasons Australian employees will leave their current role, according to Gartner’s 4Q18 Global Talent Monitor.
App downtime costs businesses over $700k per event
One hour of business-critical application downtime can cost larger companies $144,062.52 per hour, with an average repair time of over five hours.
Why application downtime costs Aussie businesses more than $762,000 on average
“These findings highlight the critical need for all Australian businesses to ensure ongoing monitoring of applications."
How AI is changing the medical industry
With NVIDIA Clara, developers can speed up their medical imaging applications and implement AI.
The Data Literacy Project expands its library of free courses
Upskilling the workforce in data literacy is fundamental to unlocking business growth.
Digital experience managers, get excited for Adobe Summit 2019
“Digital transformation may be a buzzword, but companies are trying to adapt and compete in this changing environment.”